Send SMS
Contact Us

Differential Scanning Calorimetry

Phoenix DSC High Pressure Calorimeter

Phoenix DSC High Pressure Calorimeter

We have employed a team of skilled and trained professional who have the necessary acumen to provide our respected clients with a range of Phoenix DSC High Pressure. Our clients can avail from us these products in a customized form as per their need and requirements. These products are also tested thoroughly as per the international standards of quality.

 

The features are:

 

 

Technical Specifications

 

 

Application areas:

 


Additional Information:

High Temperature Differential Scanning Calorimeter

High Temperature Differential Scanning Calorimeter

The DSC 404 F3 Pegasus®, High-Temperature Differential Scanning Calorimeter, is part of the economical NETZSCH F3-product line, which is specially tailored to the requirements of comparative material characterization and quality control.

The DSC 404 F3 Pegasus®, High-Temperature Differential Scanning Calorimeter, can be operated from -150°C to 2000°C with various DTA and DSC sensors that are easily exchangeable by the user and various furnace types (please see accessories).

The sample chamber can be purged with inert or oxidizing gases in order to remove gases evolved from the sample.

The measuring system is vacuum tight (10-4 mbar).

Differential Scanning Calorimeter (DSC)


We offer various DSC models, covering a broad temperature range from -180°C to 1750°C. The DSC 404 F1 and F3 Pegasus® are two versions for the precise determination of specific heat and caloric effects, particularly in the high-temperature range. The DSC 204 F1 Phoenix® is our premium device for the temperature range from -180°C to 700°C. It unites excellent performance and highest flexibility. Coupled to a UV add-on (Photo-DSC 204 F1 Phoenix®), it allows for monitoring the light-induced curing of, for example, paints, adhesives and resins. With the DSC 204 HP Phoenix®, measurements under increased pressure can be carried out (up to max. 150 bar). The DSC 214 Polyma is a completely new concept. Designed especially for the characterization of polymer materials, its integral approach consists not only of the DSC instrument alone, but also incorporates the entire analytical process chain from sample preparation to evaluation.
All differential scanning calorimeters discussed here operate based on the respective instrument standards as well as application or material testing specifications, including ISO 113587, ASTM E968, ASTM E793, ASTM D3895, ASTM D3417, ASTM D3418, DIN 51004, DIN 51007 and DIN 53765.
back to the diverse instrument models:

DSC Differential Scanning Calorimeter

DSC Differential Scanning Calorimeter

Our clients have inspired us to provide a wide range of DSC Differential Scanning Calorimeter that has a very high demand in the market. These products are stringently tested by our huge quality team in accordance to the standards followed globally. We can also customize these products as per the needs and demands of our clients. These products are equipped with newly developed monolithic DSC sensor and a new silver heater with long-life heating element.

The features are:

 

Technical Specification:

Applications areas:


Additional Information:

Modulated Differential Scanning Calorimeter

Modulated Differential Scanning Calorimeter

We also offer a wide gamut of Modulated Differential Scanning Calorimeter to our respected clients. These products are manufactured using radically curing material systems and its main advantage is light-curing systems that ensures fast reaction time. We also provide our clients with a customized range of these fountains as per their requirements. Our team also tests these products as per the international standards of quality.

 

The features are:


 

Technical Specifications

 

 

Application areas:

 


Additional Information:

High Pressure Differential Scanning Calorimeter

High Pressure Differential Scanning Calorimeter

Numerous physical processes and chemical reactions are influenced by the surrounding gas pressure. In practise it is therefore often necessary to conduct DSC measurements under an increased pressure.

With the high-pressure Differential Scanning Calorimeter, DSC 204 HP Phoenix®, thermal effects in a sample can be analyzed in the pressure range from vacuum to 15 MPa (150 bar) and at temperatures from -150°C to 600°C, depending on the type of gas.
The sample chamber atmosphere can be static or dynamic. The electronic pressure monitor and control, along with exact regulation of the purge gas flow, provide for excellent accuracy and reproducibility of the measurement results.
The proven CC 200 L for liquid nitrogen cooling is available for the low-temperature range.
The safety of the high-pressure DSC system has been certified through design tests and is guaranteed during operation by the appropriate safety components.

Phoenix Differential Photocalorimeter

Phoenix Differential Photocalorimeter

Inspired by the positive feedback from our clients, we also supply a wide array of Phoenix Differential Photocalorimeter. These products are tested as per the international standards of quality. Customized forms of these products are also appreciated hugely by our clients. These products are specially used for research, development and quality assurance.

 

The features are:

 

 

Technical Specifications:

 

 

Application areas:

 


Additional Information:

Polyma Differential Scanning Calorimeter

The DSC 214 Polyma delivers a powerful solution for requirements in day-to-day measuring tasks in terms of both hardware and software. It is easy to operate while still providing absolute reliability, making this innovative DSC instrument an ideal tool for the research, development, quality assurance and failure analysis of polymer materials.

Additional Information:

DSC Pegasus High Temperature Calorimeter

DSC Pegasus High Temperature Calorimeter

We are one of the leading manufacturer and supplier of a wide array of DSC Pegasus High Temperature Calorimeter. These products thermodynamic properties of ceramics and metallic high-performance materials and are crafted keeping in mind the various requirements and specifications of our clients. We stringently check these products as per the international standards of quality before it is delivered to the clients. These products are generally operated with high temperature ranging from -150°C 2400°C.

 

The features are:

 

 

Technical Specifications:

 

 

Application areas:

 


Additional Information:
X
Provide Us More Details
Is this Requirement:

One Time Regular

How soon do you want this:

Immediate After 1 month

Purpose of Requirement:

Reselling End Use Raw Material

X

Looking for Differential Scanning Calorimetry ?

    country-ico

    We will contact you soon !

    Devavrath Misra

    (Marketing Coordinator)

    Netzsch Technologies India Private Limited

    Mogappair, Chennai, Tamil Nadu, India

    More Categories

    View All Categories »
    Send SMS
    Contact Us